System-2 BTU Meter
The System-2 BTU Meter is a highly accurate instrument specifically designed for small tenant billing applications. It is provided with pre-wired temperature sensors and a single contact closure output for accumulating energy total. The System-2 is designed to be used with plenum rate cabling.

Standard Features

Single Source Responsibility
One manufacturer responsible for the manufacture, compatibility of components, and calibration of the entire BTU measurement system. ONICON is committed to providing highly accurate and reliable systems which guarantee successful installations.

NIST Traceable Calibration with Certification
Complete system-wide calibration for the entire BTU measurement system for each specific application with certification of calibration.

Precision Solid State Temperature Sensors
Custom calibrated and matched to an accuracy better than ±0.15°F from 32-200°F.

Highly Accurate Flow Meters
Insertion turbine and inline turbine flow meters which are accurate to within ±0.5% at calibrated typical flow rate and will not exceed ±2% of actual reading over an extended 50:1 turndown range (0.4 - 20 ft/s). Each ONICON flow meter is calibrated against a primary volumetric standard directly traceable to NIST with calibration certification provided.

Computational Error Within 0.05%
Thermal energy is calculated with very high resolution (typically over 10 times per second depending on flow rate). The BTU meter utilizes the digital frequency output of the flow sensor with no corresponding loss of accuracy to analog flow signal conversion.

Complete Installation Package
All mechanical installation hardware, color coded interconnecting cabling, and installation instructions are provided to insure error-free installation accurate system performance.


Typical Applications

•  Residential tenant billing
•  Commercial office tenant billing


System-2 BTU Meter Selection Guide

Model
Number

Description

Product Information
(Must have Adobe Reader 4.0  to view files)
Get Acrobat Reader here
To download file, right-click on the link and select "Save Target As..."

System-2
Model 200
The Model 200 is designed for single mode applications (either heating or cooling) and includes a single totalizing contact output. Separate LED indicators provide diagnostic information for flow and energy

Catalog Sheet
(.PDF,  181KB)

System-2
Model 210
The Model 210 is designed for dual mode applications (both heating and cooling) such as two pipe heating/cooling systems and heat pumps. Each meter includes a totalizing contact output and a mode indication contact output. Separate LED indicators provide diagnostic information for flow and energy. 
Catalog Sheet
(.PDF,  181KB)

Ordering Information for ONICON BTU Meters




ONICON Incorporated: 1500 N. Belcher Road Clearwater, Florida 33765, USA TEL: (727) 447-6140 FAX: (727) 442-5699