Chilled Water • Hot Water • Domestic Water • Steam • Natural Gas

Home >> About ONICON >> What's New at ONICON

What's New at ONICON
________________________________________

F-5500 Thermal Mass Flow Meters

F-5500 Thermal Mass Flow Meter New at ONICON
ONICON’s F-5000 Series Thermal Mass Flow Meters provide accurate mass flow measurement of natural gas, compressed air and other industrial gases. The proprietary design measures mass flow directly and does not require additional pressure or temperature compensation to deliver accurate flow rate and total data. The F-5500 is available as an inline or an insertion style meter and includes an easy to operate user interface/display. The standard version of the meter is provided with a 4-20mA analog output and an RS485 interface that is field configurable for BACnet MS/TP® or Modbus® RTU. A second output signal configuration is available that includes a 4-20mA analog output and a programmable pulse output. The pulse output model is also available with HART.

Features include:

• Native BACnet® MS/TP or Modbus® RTU communication capability.
• User interface with utility software capable of data logging, configuration and troubleshooting via micro USB port.
• Zero flow validation with report generation capability.
• Each F-5500 insertion meter is designed to be installed through a “retractor” assembly, allowing installation by hand in systems operating up to 60 psig.
• FM approval for Class 1, Div. 1 installations.
• Insertion meter available for use in pipe sizes ranging from 1½’ through 24” in diameter.
• Inline meter available for use in pipe sizes ranging from ¾ through 6” in diameter.

For more information

SYSTEM-40 BTU Measurement System

System-40 BTU Measurement System New at ONICON
The new System-40 BTU Measurement System provides highly accurate and reliable thermal energy measurement in heating and cooling systems. Its compact, no-moving-parts design and low cost make it ideal for sub-metering heating and cooling costs in condominiums, retail shops and mixed use facilities. BACnet MS/TP or MODBUS RTU outputs are available. 3 Auxiliary pulse terminals can be configured for pulse input, pulse output, a combination of both, or even with a single analog output.

Features include:

• Available for use in pipe sizes ranging from ½” through 2½” in diameter.
• No-moving-parts flow meter design with excellent accuracy and turndown.
• Precision matched platinum RTDs for accurated temperature measurement.
• Native BACnet MS/TP or MODBUS RTU are available with auxiliary pulse terminals configurable for either pulse inputs, pulse outputs, a combination of the two, or even a single analog output.
• EN1424 compliant

For more information

F-4600 Inline Flow Meter

F-4400 Portable Ultrasonic Flow Meter New at ONICON
The new F-4600 Inline Flow Meter is a compact no-moving-parts design with excellent accuracy and turndown. It is available for pipe sizes ranging from ½" through 2½" in diameter and flow rates from 0.03 to 250 GPM. The low cost F-4600 is available with a 4-20 mA output for flow rate and a scaled pulse output for totalizing flow. *Optional integral LCD display with BACnet MS/TP or MODBUS RTU is available. LCD display can be mounted up to 5 feet away from flow body for visibility.

Features include:

• Available for use in pipe sizes ranging from ½” through 2½” in diameter.
• Compact no-moving-parts flow meter design with excellent accuracy and turndown.
• Meets ANSI/NSF 61 & 372 requirements

For more information

F-3500 EXTENDED PIPE SIZE RANGE

F-3500 Electromagnetic flow meter New at ONICON
The new small pipe configuration of the F-3500 extends the low-end of the allowable nominal pipe size range from 3 inch to 1¼". The small pipe configuration of the F-3500 remains easy to insert and remove without a system shutdown via the unique hot tap design. The low maintenance design is provided ready-to-use without the need for field programming.

Features include:

• Available for use in pipe sizes ranging from 1¼” through 72” in diameter.
• No-moving-parts flow meter design with excellent accuracy and turndown.
• Easy to insert and remove without system shutdown.

For more information

F-4400 PORTABLE ULTRASONIC FLOW METER

F-4400 Portable Ultrasonic Flow Meter New at ONICON
The new F-4400 Portable Clamp-on Transit Time Ultrasonic Flow Meter is designed for temporary flow measurement. The easy-to-use, battery powered meter is accurate and reliable and includes everything you need in a single weathertight carrying case.

Features include:

• Available for use in pipe sizes ranging from ½” through 48” in diameter
• Clamp-on design does not penetrate the pipe wall in any way.
• Battery operated design includes a built-in data logger
• 4-20 mA output also available when operating from 24V battery charger.

For more information

 

 

11451 Belcher Road South, Largo, FL 33773 • USA